Results

Capacity factor 32%: within the typical 20–45% range for Onshore wind. That equals running at full power for 2,800 of 8,760 hours.
Capacity factor
32%
0.32 as a fraction
Full-load hours
2,800h
in the 8,760-hour period
Average power
15.98MW
vs 50 MW nameplate
Energy
140GWh
Capacity
50MW
Typical for Onshore wind
20–45%
Specific yield
2,800kWh/kW·yr
annualised energy per kW
Your capacity factor vs typical values

Typical capacity factors by technology

TechnologyTypical rangeFull-load hours/yrWhy
Nuclear80–93%7,008–8,147baseload, refuelling outages every 18–24 months
Geothermal70–90%6,132–7,884constant heat source
Biomass / biogas50–85%4,380–7,446fuel-limited, dispatchable
Gas combined cycle45–65%3,942–5,694dispatched by price; mid-merit
Coal35–65%3,066–5,694declining use in many grids
Offshore wind38–55%3,329–4,818stronger, steadier sea winds
Hydropower30–60%2,628–5,256water availability, dispatch & storage
Onshore wind ◀20–45%1,752–3,942wind resource, turbine specific power
Concentrated solar (with storage)30–55%2,628–4,818storage hours extend output
Utility solar PV, tracking20–32%1,752–2,803trackers follow the sun
Utility solar PV, fixed12–25%1,051–2,190night & clouds; latitude
Rooftop solar PV9–20%788–1,752non-optimal tilt, shading, heat
Gas / oil peaker2–15%175–1,314runs only at demand peaks
Battery storage (discharge)8–20%701–1,752cycles per day × duration
  • Ranges summarise US fleet data (EIA Electric Power Monthly, Table 6.07) and global new-build averages (IRENA); individual plants and years vary widely.
  • Capacity factor is not efficiency: a 25% solar capacity factor reflects night and weather, not wasted energy. For dispatchable plants it reflects how often the grid calls on them.
  • Use AC nameplate for solar when comparing with other technologies (DC-based figures look lower).

Free calculator by GreenEnergy.net