Home energy calculator

Air conditioner calculator: running cost per hour, month and year, plus the right BTU size

Sizes an air conditioner for your room (BTU and kW) from floor area, ceiling height, sun exposure, climate and occupants, then calculates the electricity it uses and what it costs per hour, day, month and cooling season from its SEER or EER.

Editable share link Branded PDF report Free · no sign-up

Results

Recommended size: about 6,800 BTU/h (2 kW); the nearest standard unit is 7,000 BTU. Running it 8 h a day costs 0.37 € per day.
Cooling cost per season
€27.75
111 kWh over 75 days
Cost per hour
€0.046
0.18 kW average draw
Cost per day
€0.37
Cost per month of use
€11.10
Recommended size
6,800BTU/h
2 kW cooling · 0.57 tons
Unit used for costs
7,000BTU/h
2.05 kW · max input 0.34 kW
Efficiency (W/W)
6.1
= 20.8 BTU/Wh
CO₂ per year
39kg
Seasonal cooling cost by efficiency
Cost per day vs hours of use

Quick sizing guide (average room, warm climate)

Room areaBTU/hkW cooling
10 m² (108 ft²)2,7000.8
15 m² (161 ft²)4,1001.2
20 m² (215 ft²)5,5001.6
25 m² (269 ft²)6,8002
30 m² (323 ft²)8,2002.4
40 m² (430 ft²)10,9003.2
50 m² (538 ft²)13,6004
70 m² (753 ft²)19,1005.6
  • Sizing ≈ 80 W/m² (25 BTU/h per ft²) adjusted for ceiling height, climate, sun, occupants (+600 BTU/h each beyond two) and kitchens (+4,000 BTU/h), in line with ENERGY STAR guidance. Poorly insulated rooms may need 20–30% more.
  • Running cost = capacity ÷ efficiency × load factor × hours. SEER already reflects part-load operation; for EER (full-load) ratings a load factor of ~70% is more realistic.

How this air conditioner calculator works

Most people ask two things about an air conditioner, one before buying and one after: what size do I need? and what will it cost to run? This calculator answers both.

Sizing. It starts from roughly 80 W of cooling per square metre of floor area (about 25 BTU/h per square foot), which matches the ENERGY STAR room-size table for an average room. It then scales for ceiling height, climate (from mild northern European summers to Gulf-state heat), sun exposure (shaded, average, west-facing glass, top floor under a roof), extra occupants (each person beyond two adds about 600 BTU/h, or 175 W of body heat) and kitchens (+4,000 BTU/h). The result is rounded up to the next standard unit size: 5,000, 6,000, 7,000, 9,000, 12,000, 18,000, 24,000 BTU and so on.

Running cost. Electrical input is cooling capacity divided by efficiency. You can enter efficiency in any of the common formats: European SEER (W/W), US SEER or SEER2 (BTU/Wh), EER (BTU/Wh at full load) or a full-load COP. Because inverter units spend most of their time at part load, the calculator multiplies the full-load input by an average load factor (55% by default) and then by your hours per day, days per season and electricity price. An optional heating mode adds the cost of using a reverse-cycle unit as a heat pump.

The formula

Q_required (W) = area × 80 × (ceiling ÷ 2.5) × f_climate × f_sun + 175 × (people − 2) [+ 1,170 kitchen] BTU/h = W × 3.412

P_input (kW) = Q_unit (kW) ÷ efficiency (W/W) [US SEER or EER ÷ 3.412 → W/W] kWh/season = P_input × load factor × hours/day × days Cost = kWh × electricity price

Worked example: a 25 m² living room

With the defaults (25 m², 2.5 m ceiling, warm-summer climate, average sun, two people), the room needs about 6,800 BTU/h (2.0 kW) of cooling, so the calculator picks a standard 7,000 BTU (2.05 kW) unit.

At an EU SEER of 6.1 (A++), the unit’s maximum electrical input is 2.05 ÷ 6.1 = 0.34 kW. At a 55% average load it draws about 0.18 kW, which costs €0.046 per hour at €0.25/kWh. Running 8 hours a day costs €0.37 per day or about €11 for a month of use. Over a 75-day cooling season that is 111 kWh and roughly €28, and about 39 kg of CO₂ on a 350 g/kWh grid.

The efficiency chart shows why the label matters: the same cooling from a 3 W/W unit (typical of portable and old window units) would cost €56 a season, twice as much, while an 8.5 W/W premium unit would cost about €20.

How to read the results

  • Cooling cost per season is the headline number for budgeting. Change days of use to match your climate; the climate selector fills in a typical value.
  • Cost per hour, day and month help decide whether running the AC overnight or all day is affordable.
  • Recommended size is in BTU/h, kW and refrigeration tons (1 ton = 12,000 BTU/h). If you enter your own unit capacity, the verdict tells you whether it is undersized, oversized or about right.
  • Efficiency (W/W) converts whatever rating you entered so you can compare units across European and US labels.

Typical values

Unit type Typical efficiency Input for 3.5 kW of cooling
Portable single-hose EER 2.0–2.6 W/W 1.3–1.8 kW
Window unit (older) EER 2.6–3.2 W/W (9–11 BTU/Wh) 1.1–1.3 kW
Split, basic (A+) SEER 5.6–6.1 W/W 0.6–0.7 kW (seasonal avg. lower)
Split, efficient (A++/A+++) SEER 6.1–8.5+ W/W 0.4–0.6 kW
US central AC SEER2 13.4–20 BTU/Wh 0.6–0.9 kW

Tips to cut air-conditioning costs

  • Set 24–26 °C, not 20 °C. Each degree lower raises cooling energy by roughly 6–10%.
  • Block the sun before it enters. External shutters or awnings on west and south windows can reduce the cooling load more than any upgrade to the unit.
  • Use inverter units and let them run steadily rather than switching on and off at full blast.
  • Clean filters monthly in the cooling season; clogged filters cut efficiency noticeably.
  • Pair with solar. Cooling demand peaks when solar output does; see the solar panel calculator.
  • Use it for heating too. In winter a split unit is an efficient heat pump; compare it with your current system in the heat pump calculator.

Limitations

The sizing rule assumes a reasonably insulated room with normal window areas. Rooms with large glazed facades, poor insulation or high internal gains (servers, many people) need a proper heat-gain calculation (for example Manual J in the US or EN 12831-style methods in Europe). Real consumption depends on thermostat setpoint, humidity and how often doors are opened; the load factor is a single average. Cooling-season length varies widely between years. Standby consumption of the indoor unit (typically 1–5 W) is not included — see the standby power calculator.

Method & assumptions

Required capacity Q = area × 80 W/m² × (ceiling ÷ 2.5 m) × climate factor × sun factor + 175 W per extra person (+1.17 kW for kitchens), rounded up to the next standard size. Electrical input = Q ÷ efficiency (US SEER/EER in BTU/Wh ÷ 3.412 = W/W). Energy = input × load factor × hours × days. Heating mode: energy = 50% of rated capacity × hours × days ÷ SCOP.

Frequently asked questions

How much does it cost to run an air conditioner per hour?
Divide the unit's cooling capacity by its efficiency to get the electrical input, multiply by the average load and by your electricity price. A modern 2 kW (7,000 BTU) split unit with SEER 6.1 draws about 0.2 kW on average, roughly €0.05 per hour at €0.25/kWh. An old window unit of the same size can cost three times as much.
What size air conditioner do I need for my room?
As a rule of thumb, about 80 W of cooling per m² (25 BTU/h per ft²) for an average room with a 2.5 m ceiling. That gives roughly 5,000–6,000 BTU for 15–20 m², 7,000–9,000 BTU for 25–30 m² and 12,000 BTU for 40–45 m². Add capacity for sunny or top-floor rooms, kitchens and more than two occupants.
What is the difference between SEER and EER?
EER is efficiency at one full-load test point; SEER is a seasonal average that includes part-load operation, so it is higher. In Europe SEER is given in W/W (6.1 or more earns A++); in the US it is given in BTU/Wh (divide by 3.412 to convert to W/W). US SEER2 values are about 4–5% lower than old SEER for the same unit.
Is a bigger air conditioner better?
No. An oversized unit cools the air quickly and switches off before it has removed enough moisture, leaving the room cold and clammy. It also cycles on and off more, which wastes energy and wears the compressor. Aim for 85–140% of the calculated requirement; inverter units tolerate oversizing better.
How many kWh does an air conditioner use per day?
A small 2–2.5 kW inverter split unit typically uses 1–3 kWh per day in summer when run for 8 hours. A 3.5 kW unit in a hot climate can use 5–10 kWh, and portable units or old window units often use 8–15 kWh for the same cooling.
Is it cheaper to heat with an air conditioner?
Usually yes. A reverse-cycle air conditioner is an air-to-air heat pump with a seasonal COP of 3.5–5, so it delivers 3.5–5 kWh of heat per kWh of electricity. That is far cheaper than electric resistance heaters and often cheaper than gas.

Sources & references

  1. ENERGY STAR: Room air conditioner sizing guidance
  2. U.S. DOE: Room air conditioners
  3. European Commission: Energy labelling of air conditioners (Regulation 626/2011)
  4. IEA: The Future of Cooling