Ratio of actual AC energy output to the theoretical output implied by plane-of-array irradiation and nameplate capacity; a location-independent quality metric for PV plants.

The performance ratio (PR), defined in IEC 61724-1, normalises a PV system output by the solar resource it actually received, so plants in different climates can be compared on technical quality.

PR = Yf / Yr = [EAC / PSTC] / [HPOA / GSTC]

Yf is final yield (kWh per kWp) and Yr reference yield (plane-of-array irradiation in kWh/m² divided by 1 kW/m², i.e. peak sun hours). A PR of 0.82 means 18% of the theoretical STC energy was lost.

Typical values: well-designed modern utility plants 80–88%; residential rooftops 75–85%; older or poorly maintained systems 60–75%. Main loss contributions in a sunny climate:

  • Cell temperature above 25 °C: 4–10% (see temperature coefficient)
  • Soiling: 1–5%
  • Inverter conversion: 1.5–3%
  • DC and AC cabling, mismatch: 1.5–3%
  • Shading, reflection, low-irradiance and spectral effects: 2–5%
  • Clipping and availability: 0–3%

PR is lower in hot climates and in summer, and slightly higher in cool, sunny conditions. Temperature-corrected PR is used in O&M contracts so that warranted values are not penalised by weather.

Related terms

All terms →
  • Specific yield

    Annual energy produced per unit of installed PV capacity, expressed in kWh/kWp per year; combines solar resource and system performance.

  • Temperature coefficient

    The percentage change in a PV module power, voltage or current per degree Celsius of cell temperature away from 25 °C.

  • Soiling loss

    Reduction in PV or CSP output caused by dust, pollen, bird droppings, snow or other deposits blocking light from reaching cells or mirrors.

  • Peak sun hours

    Daily solar irradiation expressed as the equivalent number of hours at 1,000 W/m²; numerically equal to kWh/m² per day.

  • Inverter clipping

    Energy lost when the DC power available from a PV array exceeds the inverter AC rating, so the inverter caps output at its maximum.