Heat rate

The fuel energy a thermal power plant consumes per kWh of electricity generated; the inverse of efficiency, usually in BTU/kWh or kJ/kWh.

The heat rate measures thermal plant efficiency the other way round: how much fuel heat is needed per unit of electricity. A lower heat rate is better. It is standard in the US power industry and in plant performance guarantees, and is the key input for fuel cost per MWh.

Efficiency η = 3,412 / heat rate (BTU/kWh) = 3,600 / heat rate (kJ/kWh)
Heat rate (BTU/kWh) = 3,412 / η
Example: 6,400 BTU/kWh → 3,412 / 6,400 = 53.3% (HHV)
Fuel cost (USD/MWh) = heat rate (MMBtu/MWh) x fuel price (USD/MMBtu)

Typical full-load heat rates (US EIA, HHV basis):

  • Modern CCGT: 6,200–6,800 BTU/kWh (50–55% HHV, 56–62% LHV)
  • US gas combined-cycle fleet average: about 7,500 BTU/kWh
  • Open-cycle gas turbines: 9,500–11,500 BTU/kWh
  • Coal steam plants: 9,500–10,500 BTU/kWh (fleet average about 10,000; supercritical about 8,700)
  • Nuclear: about 10,400 BTU/kWh thermal equivalent (33% efficiency)

Heat rates rise (worsen) at part load, during start-ups and at high ambient temperatures, which affects plants that cycle to balance variable renewables. Gross versus net output (after auxiliary consumption) and HHV versus LHV must be specified; see calorific value.

Related terms

All terms →
  • Calorific value (HHV / LHV)

    The heat released by complete combustion of a unit quantity of fuel; the higher (gross) value includes condensation heat of water vapour, the lower (net) value excludes it.

  • Combined-cycle gas turbine (CCGT)

    A power plant that runs a gas turbine and uses its hot exhaust to raise steam for a second, steam turbine, reaching electrical efficiencies of 55–64%.

  • MMBtu

    One million British thermal units (1.05506 GJ, 293.07 kWh); the standard pricing unit for natural gas and LNG in the United States and Asia.

  • BTU (British thermal unit)

    A traditional unit of heat, approximately the energy needed to raise one pound of water by one degree Fahrenheit; 1 BTU (IT) = 1,055.06 J.

  • Open-cycle gas turbine (OCGT)

    A simple-cycle gas turbine that exhausts hot gas directly to the atmosphere, trading lower efficiency (33–42%) for fast start and low capital cost, used mainly for peaking.

  • CHP (Combined Heat and Power)

    Simultaneous generation of electricity and useful heat from one fuel input, reaching total efficiencies of 75–90% versus about 35–60% for power-only plants.